Procedures before discharge.
All personnel involved should have a thorough understanding of safety precautions required to handle the product and have read the company safety manual.
For flammable loads, ensure that the offload area is free of ignition sources.
Consider the positioning of any mobile firefighting apparatus; would it still be accessible in an emergency? Is it upwind of the tank?
Check which silo the load is to be pumped into. Is there adequate space available? Verify this. If there is product in the receiving silo, check that the new load is the same product and that batch mixing is acceptable.
Where company procedures require test samples to be taken prior to pumping, alert lab technicians to sample the load and await verification of acceptance.
Ensure that the vehicle is parked in a suitable position for offload.
Check the security seals!
The trailer should be positioned so that the back of the tank is lower than the front of the tank. This will ensure that the product drains naturally to the discharge valve and minimises the amount of residual product left in the tank.
The vehicle should be securely braked, and the wheels choked where necessary.
Attach the earthing connection; this is normally found on the side of the tank.
In the picture above, the earthing connection can just be seen behind the blue steel strut.
Check that hoses of the correct length, with the correct thread, gaskets and fittings are available. Ensure these are clean and ready for use. Have they previously been used to offload a different product? Ensure that the products are compatible.
Assemble equipment and solvent to clean out the hoses and the valve area, after the tip.
Check that receiving lines are clear and that receiving valves are correctly set to pump the load.
Examine tank valves; the end cap should be present. The butterfly valve handle should be securely closed, i.e. the handle above the valve should be flat against the tank as in the picture above and the foot valve (brake handle at the side) should be in the closed position. The foot valve is operated on a spring mechanism, pressing the handle downwards stretches the spring, and in stretching the spring the valve is pulled open. Clicking the handle upwards releases the spring and closes the valve.
It is important to understand the order of the three ‘closing mechanisms’. The foot valve or emergency brake closes next to the product. In the event of an accident it is designed to close off the flow of the product quickly; activate it by applying pressure to it with your foot! Or standing at the side of the tank and pulling the wire that it is attached to. This will activate the spring and pop the handle to the ‘up’ position. You will note in the section "Procedures after discharge" the first valve action is to close the foot valve, prior to dismantling the hose or closing any other valve. If, for example, someone was to close the butterfly, then the foot valve, and then dismantle the hose, this would simply trap product between the two valves; this product could gel or harden.
The butterfly valve is next and is the ‘main’ closure. The end cap is last.
Having checked that the foot and butterfly valves are securely closed, remove the end cap and fasten the hose securely. Attach the other end of the hose to the pump, or end of the plant’s receiving line.
Open the manlid situated on the top of the tank. Note that this is heavy; it should be opened fully and laid down carefully.
Check that the receiving team are all in place and obtain authority to commence tip.
Open the valves at the receiving end.
Open the tank’s butterfly valve and then the foot valve. Let the product run into the hose until it is full. Turn on pump (following local guidelines for correct procedure; it may for example need primed).
Procedures during discharge.
Whilst the tank is emptying, it should not be left unattended at any stage or for any reason. Continually check that the hoses are not leaking, that the silo space is indeed adequate and that all personnel present are observing safety rules.
Procedures after discharge
Check that the tank is completely empty.
Close down the pump and secure the intake lines.
Close the tank foot valve.
Dismantle hose from pump, or receiving end lines, and drain any residue from the hose into a suitable receptacle.
Clean receiving end line of any residual product.
Dismantle hose from tank, again taking care not to spill any remaining product.
Clean down the tank valve outlet and surrounding area, ensuring that the threads and the area of the valves, that can be reached, are completely free of product. Wash the end cap to ensure it is free of product spill before it is replaced onto the tank.
Close the butterfly valve securely.
Replace the end cap.
Close the manlid securely.
Remove the earthing connections.
Clean hoses, gaskets and fittings, ready for use next time.
Ensure any mobile firefighting apparatus is put back in place.