Specifications for a T11 'Standard Chemical Tank'

Close window


Cassilon operates type T11 tanks which cover the movement of the majority of chemical liquids. In fact the 'Standard Tank' of the industry, these units are specified as follows:

  • 4.9mm /over 3/16" thickness of stainless steel for the shell
  • Maximum Working Pressure of 4 Bar
  • Minimum Test Pressure of 6 Bar
  • Bottom Discharge Butterfly Valve, coupled with a foot or emergency valve and finished with an end cap, thus giving three closures
  • Safety Relief Valve/s

In addition to the requirements of the regulations:
  • 50mm /almost 2" of insulation
  • Steam Heating Tubes around the tank to facilitate the heating of the tank contents. Electrical heating for the carriage of liquids at elevated temperatures is not considered a standard fitment and would have to be specially requested
  • Suitable ladders and walkways to gain access to the top of the unit.
  • PTFE gaskets and seals